Office     (04) 499-0010
 Fax        (04) 499-0040

 sales@csinz.com

LAE Electronic - Humidity and Temperature Displays

LTS12 Configurable Display

 

  • Panel display.

  • Indicates the instant temperature and the minimum and maximum measured values.

  • Easy selection of scale in °C/°F, of fixed or automatic resolution, of the input for PTC/Pt100/TC/0..1V • Range

  • -100...+900°.

  • Runs 12VAC/DC, 24VAC/DC and on mains power supply.

Applications: measurements in cold stores, high temperature ovens or furnaces and plants in which the thermometer requires configuration on the spot.

 

FUNTIONS

LTS12 Series: °C and % RH

PT D/I/E

TC D/I/E

AV D/I/E

Input Type

PTC1000

Pt100

TC “J”

TC “K”

0÷1V

Range

-50÷150°C

-100÷600°C

-50÷700°C

-50÷900°C

0÷100%RH

Accuracy

S1*=±0.2°C; S2*=±1°C

±3°C

±0.1%

Resolution

S1*=0.1°C; S2*=1°C

1.0°C

0.1%

Power supply

..D=12Vac/dc/ ..I=24Vac/dc/ ..E=230Vac ±10%; 2W

Front Protection

IP54

LT12 Wide Range Display

 

  • Panel display.

  • Range between –100 and +900°.

  • It’s available in the version with °C or in the version with °F.

  • 0.1° or 1° resolution.

  • Sensor PTC/Pt100/TC/0..1V.

  • Runs on 12VAC/DC, 24VAC/DC and on mains power supply.

Applications: accurate measurements in cold stores, refrigerating cabinets and tables, greenhouses, seasoning cells, high temperature ovens or furnaces.

 

 

 

 

FUNTIONS

LT12 Series: °C and % RH

PT D/I/E

TC D/I/E

AV D/I/E

Input Type

PTC1000

Pt100

TC “J”

TC “K”

0÷1V

Range

-50÷150°C

-100÷600°C

-50÷700°C

-50÷900°C

0÷100%RH

Accuracy

S1*=±0.2°C; S2*=±1°C

±3°C

±0.1%

Resolution

S1*=0.1°C; S2*=1°C

1.0°C

0.1%

Power supply

..D=12Vac/dc/ ..I=24Vac/dc/ ..E=230Vac ±10%; 2W

Front Protection

IP54