MAMAC - IP Sensor Appliance
Anyone who can surf the web, can now do sensor monitoring,
control, data logging, and email alerts without any training or
custom software.
All you need is a web browser running on any laptop, PDA, or cell phone anywhere in the world.
Click Here to view some Sample Pages
TEST DRIVE OUR DEMONSTRATION UNIT
The
Maverick IP Sensor Appliance incorporates a web server, analog/digital inputs and relay outputs. Power the appliance with any 24VAC transformer, plug it into a hub/router, launch any web browser, punch in the default IP and connect. No custom software to load, no discovery routines, no custom cables, or training.
The IP Sensor Appliance serves up static web pages with dynamic data
updates every
second
or two. Most users can set up and utilize the appliance without any
training or support in less than
5 minutes
due to the innovative and familiar web browser based configuration.
The
Maverick is an ideal low cost solution for light commercial, residential and remote monitoring applications. The appliance can also be used to enhance existing HVAC control systems by adding email alerts and data logging to critical points.
SPECIFICATIONS:
|
Supply Voltage: 24 VAC/VDC
Supply Current:
250 mA (6 VA)
Input Impedance:
125K ohms (VDC or Digital) 250 ohms (4-20 mA)
Digital Input:
10.00 VDC maximum
Output Relay Rating:
250 VAC @ 5.0 Amps UL Listed
Ethernet:
10-Base T
IP Assignment:
Static or DHCP Email: SMTP to two email addresses
|
Data Logging: 2048 samples each input
Logging Interval:
1.0 second to 99.99 hours
Environmental:
10-90%RH non-condensing
Operating Temp:
-40°F-125°F (-40°C-52°C)
Storage Temp:
-40°F-150°F (-40°C-66°C)
Enclosure:
UL 94V-5-O Polycarbonate plastic
Termination:
Removable terminal blocks 16 Ga max, RJ-45 Ethernet jack Weight: 0.5 lbs. (.25 kg) |
ORDERING INFORMATION: IP-PC-101-

Example: IP-PC-101-44-VDC: 4 VDC Inputs and 4 Relay Outputs
GENERAL:
The Maverick IP Sensor Appliance has an embedded lean TCP-IP stack
including HTTP, SMTP, DHCP, DNS, FTP, and ARP.
The Maverick also has XML embedded with formatted input & output
data. In this way, the Maverick can communicate directly with any IT
system which has an XML parser. Similarly, any simple JavaScript can
be used to communicate and acquire HTML data. These unique features
enable the Maverick to function as a extremely low cost XML & HTML
node for large enterprise IT systems.
INPUTS & OUTPUTS:
The Maverick is available in two I/O versions:
1. First
version has 8 analog or digital inputs.
2. Second
has 4 analog or digital inputs and 4 relay outputs.
The analog inputs can be specified to be voltage or current inputs.
On voltage input versions, the appliance can be field configured for
0-5 or 0-10 VDC inputs. Both analog versions (voltage or current)
accept 10 VDC maximum as digital input. The output relays are rated
for 5 Amps @ 250 VAC and can be used for pilot duty or light load
switching directly.
Any input can be assigned to control relays 1 through 4. An output
can be controlled by an input, and/or by time based control. If an
output has both input and time control, the time based control will
force the output on and override the input during "ON" time.
However, if time based control is off, input control will take over
and force the output on if the value is above/below set point.
The most powerful feature the Maverick has is browser initiated
manual control. Any output can be controlled remotely with a web
browser running on a cell phone, PDA or a laptop. In this way, if an
email alert is received, the user can remotely control the output
manually and handle the emergency. Using email alerts, the load can
be
operated
manually until a convenient time to despatch a service technician.
EMAIL ALERTS:
Biggest short coming of all existing control systems is their
inability to directly send email alerts and alarms. The Maverick
appliance has a very user friendly email alert capability and can
send email alerts to up to two different addresses. Email alerts can
be configured on all inputs and the Maverick also has the capability
to attach a comma separated log file to the email alert. In this
way, the user does not only receive an alert but also can parse the
log file and know why the alert is coming.
The Maverick appliance can also send email alerts in case of a power
outage. The appliance logs the time the power went out and when the
power is restored, sends an email with time stamp when the power
went out and when it was restored.
Similarly, the appliance can be configured to send an email if the
DHCP IP assignment has been changed. In this way, if the Maverick is
running as a DHCP client, it can keep the users abreast of it's DHCP
IP assignment and the user does not have to discover the appliance.
DATA LOGGING:
The appliance can log 2048 samples for each input. The logging
interval can be from 1 second to 99.99 hours. Data is logged in a
standard CSV file and can be reviewed with Notepad, WordPad, Excel
or any other software application which can open comma separated
files.
The Maverick also uses a JavaScript which runs on the web browser to
display the logged data as a graph. The X scale (sensor value) and
the Y scale (time) on the graph can be adjusted. As a result, the
graph can be plotted to show only the relevant data.